| Time Domain Reflectometer (TDR) |
|

|
TDR (Time Domain Reflectometry)
- Up to 20 GHz TDR Bandwidth with 15 ps Reflected Rise Time and 12 ps Incident Rise Time
- Lowest Noise for Accurate Repeatable TDR Measurement Results – 600 μVRMS at 50 GHz
- Independent Sampler Deskew Ensures Easy Fixture and Probe De-embedding
- Industry’s Only Mainframe to Accommodate up to Four True Differential TDR or Electrical Channel Pairs for Increased System Versatility
S-parameters Measurements
- Up to 20 GHz Differential, Single Ended, Mixed-Mode; Insertion, Return Loss, Frequency Domain Crosstalk
- PCI Express, Serial ATA, Infiniband, Gigabit Ethernet Manufacturing and Standard Compliance Testing for Gigabit Signal Path and Interconnects – Including Eye Mask Tests
- Intuitive, Easy and Accurate for Serial Data, Gigabit Digital Design and Signal Integrity
- Fast and Accurate Automated Multi-port S-parameter Measurements with Command Line Interface
Jitter, Noise, BER and Serial Data Link Analysis
- Measures and Separates Deterministic Data Dependent Jitter from Random Jitter
- Measures Vertical Noise Separating Deterministic Data Dependent Noise from Random Noise
- Highly Accurate BER and Eye Contour Estimation
- FFE/DFE Equalization
- Channel Emulation
- Linear Filter for Fixture De-embedding, Linear Filtering
|
| |
| Vector Network Analyzer (R&S ZVB 8) |
|

|
Vector Network Analyzer (R&S ZVB 8)
The network analyzers of the ZVB 8, frequency ranges up to 8GHz, with four test ports, feature an innovative reflectometer concept that sets new standards. Each test port is provided with a separate generator, measurement receiver and reference receiver. This concept of independent reflectometers allows parallel measurements to be performed, a precondition for higher levels of performance even as the complexity of measurement tasks steadily increases. Based on this concept, the ZVB is especially able to carry out multiport measurements extremely quickly, e.g. on balanced SAW filters, duplex filters or antenna switching modules.
- Multiport measurements
- Balanced measurements, mixed-mode S parameters
- Separate generator for each test port
- Parallel measurements
- Calibration techniques:
- TOSM, TRL/LRL, TOM, TRM, TNA
- Multiport calibration techniques
- Calibration unit for automatic calibration
- Extremely short measurement times with simultaneous data transfer
- Dynamic range >123 dB
- IF bandwidths 1 Hz to 500 kHz
- Power sweep range 50 dB
- Up to 20 001 points per trace and traces
- More than 100 independent channels
- Parallel loading of setups (preloading, setup swap)
- Operation via front-panel keys or mouse and keyboard
- Online help
- Measurement wizard
|
| |
| 3.5GHz Digital Phosphor Oscilloscope (DPO7354) |
|

|
Digital Phosphor Oscilloscope (DPO7354)
- High sample rate on all models, on all channels, to capture more signal details (transients, imperfections, fast edges)
- 40GS/s on one channels
- High bandwidth up to 3.5GHz, matched across 4 channels and enabled by Tektronix proprietary DSP enhancement. The user-selectable DSP filter on each channel provides magnitude and phase correction plus extension to 3.5GHz for more accurate signal fidelity for complex measurement. The DSP filter on each channel can also be switched off to take advantage of true 2.5GHz analog bandwidth for applications needing the highest available raw data capture
- Very low jitter noise floor and vertical accuracy for very accurate measurements
- Longest acquisition of the industry to provide more resolution and longer time sequence
- Standard 10 million data points per channel
- Easily manage this deep record length, provide detailed comparison and analysis of multiple waveform segments with the MultiView Zoom feature. Automatically scroll through deep records visually or create a math expression to instantly highlight differences
- Highest performance probing solutions for differential and single-ended voltage signals as well as current measurement, because accurate design verification depends on high bandwidth access to critical signals and high-fidelity signal capture
|
|